Automatic Insulating Oil Kinematic Viscosity Tester | VS-9807
Products Details
VS-9807 Automatic Insulating Oil Kinematic Viscosity Tester is developed for the precise determination of kinematic viscosity and dynamic viscosity calculation of Newtonian liquid petroleum products. Serving as a crucial analytical solution complementary to our transformer oil water content tester instruments, the system measures the flow time of a specified liquid volume through a calibrated glass capillary viscometer under gravity at a constant temperature, automatically calculating the viscosity value according to international testing standards.
The system utilizes advanced fuzzy PID temperature control technology to achieve exceptional temperature stability and measurement accuracy. Multiple preset temperature points including 20°C, 40°C, 60°C, 80°C, and 100°C are available, while users can also set any custom temperature between ambient temperature and 120°C.
A high-definition color touchscreen interface provides an intuitive operating environment. The instrument can simultaneously operate two capillary viscometers under the same temperature conditions, significantly improving laboratory efficiency and sample throughput.
The entire testing procedure is fully automated, including sample injection, sample lifting, timing detection, waste discharge, cleaning, drying, viscosity calculation, result storage, and report printing. The system automatically eliminates abnormal timing results that exceed allowable tolerance limits and calculates the average value according to standard testing requirements.
With intelligent data management, built-in thermal printing, automatic calibration functions, and dual-station operation capability, the VS-9807 delivers reliable and repeatable viscosity analysis for modern oil testing laboratories.
Specification
| System Specifications | |
| Parameter | Specification |
| Model | VS-9807 |
| Standard | GB/T265-1988 |
| Display | Color LCD Touch Screen |
| Test Stations | 2 Positions |
| Temperature Range | Ambient Temperature to 120°C |
| Preset Temperatures | 20°C, 40°C, 60°C, 80°C, 100°C |
| Custom Temperature Setting | Ambient Temperature to 120°C |
| Temperature Control Accuracy | ±0.01°C |
| Timing Range | 0–999.9 Seconds |
| Timing Accuracy | 0.1 Second |
| Test Repetitions | 1–8 Times |
| Data Processing | Automatic Calculation |
| Printing | Built-in Thermal Printer |
| Automation Functions | |
| Function | Description |
| Sample Injection | Fully Automatic |
| Timing Detection | Fully Automatic |
| Waste Discharge | Fully Automatic |
| Cleaning | Fully Automatic |
| Drying | Fully Automatic |
| Data Storage | Automatic |
| Result Calculation | Automatic |
| Power Supply | |
| Parameter | Specification |
| Input Voltage | AC 220V ±5% |
| Frequency | 50Hz ±5% |
| Power Consumption | 1100W |
| Environmental Conditions | |
| Parameter | Specification |
| Operating Temperature | 5°C to 35°C |
| Relative Humidity | 10% to 80% RH |
| Test Capillary Parameters | |
| Parameter | Specification |
| Capillary Quantity | 2 |
| Viscosity Constant Input | User Programmable |
| Capillary Diameter Input | User Programmable |
| Automatic Error Judgment | Supported |
| Tolerance Verification | Automatic |
Standard Accessories
- Main Test Unit
- 50mL Sample Cup
- Power Supply Cable
- Cooling Water Circulation Pump
- Cooling Water Hose Set
- Hose Clamps
- Drain Hose
- Thermal Printer Paper
- Grounding Cable
- Spare Fuses
How the System Works
The VS-9807 measures the time required for a specific volume of oil to flow through a calibrated glass capillary viscometer under gravity at a precisely controlled temperature. The instrument automatically records flow time, applies the capillary constant, and calculates the kinematic viscosity value.
During testing, the system automatically performs sample injection, capillary filling, timing detection, viscosity calculation, waste discharge, cleaning, and drying operations without operator intervention. Multiple test cycles can be performed automatically, and the instrument removes invalid readings before calculating the final viscosity result.
Features
- Fully automatic kinematic viscosity testing
- Compliant with GB/T265-1988 standards
- Dual-station simultaneous testing
- Automatic sample injection system
- Automatic sample lifting and detection
- Automatic timing and viscosity calculation
- Automatic waste discharge
- Automatic capillary cleaning
- Automatic drying function
- High-definition color touchscreen
- Fuzzy PID temperature control technology
- Temperature control accuracy ±0.01°C
- Temperature range up to 120°C
- Multiple preset test temperatures
- Custom temperature programming
- Automatic invalid data elimination
- Intelligent average value calculation
- Built-in thermal printer
- Automatic data storage
- Fast and reliable operation
Applications & Use Cases
Application Scenarios
-
Transformer Oil Laboratories: Used for viscosity evaluation of transformer insulating oils.
-
Power Utilities: Supports oil condition assessment and preventive maintenance programs.
-
Transformer Manufacturers: Provides quality control testing during transformer production.
-
Oil Analysis Laboratories: Suitable for petroleum and lubricant viscosity analysis.
-
Industrial Facilities: Used for lubrication oil quality monitoring and maintenance.
-
Research Institutions: Supports research and development of insulating oils and specialty fluids.
Functional Applications
-
Transformer Oil Viscosity Testing
-
Insulating Oil Quality Assessment
-
Lubricating Oil Analysis
-
Petroleum Product Testing
-
Dynamic Viscosity Calculation
-
Oil Condition Monitoring
-
Utility Laboratory Testing
-
Transformer Manufacturing Quality Control
-
Preventive Maintenance Programs
-
Research and Development Applications
Weshine Advantages
Weshine Electric is a professional manufacturer of transformer testing instruments and high-voltage diagnostic equipment. Positioned as a premier solution within our broader insulating oil tester range, the VS-9807 Automatic Insulating Oil Kinematic Viscosity Tester combines advanced PID temperature control, intelligent automation, dual-station testing capability, and precision measurement technology. Designed for utilities, transformer manufacturers, oil laboratories, and industrial users, Weshine solutions provide accurate, reliable, and efficient viscosity analysis for modern power industry applications.